Home > Error During > Error During Configuration Of The Host

Error During Configuration Of The Host

Contents

Not a big deal as ESX(i) is pretty easy to install, and depending on the environment often easy to reconfigure. Privacy Policy Site Map Support Terms of Use Our website uses cookies Cookies help us deliver our services. Reply #6 by Chris Ma on November 3, 2010 - 12:05 am Thanks for the post! Your quote: "I tried booting from a linux disk and formatting ext3" indicates that you have existing partitions. http://invictanetworks.net/error-during/error-during-the-configuration-of-the-host.html

Unmount each of these and try the restore or mount procedure again. Test adding the NFS Datastore manually (http://www.veeam.com/kb1284):1.       Within a vSphere Client select the ESX(i) host that the NFS Datastore is Do not create new partitions. Like Show 0 Likes (0) Actions 4. Then before creating any new shares I enabled the NFS option and checked the status, and yes the service was running.

Error During Configuration Of The Host

Hanccocka I may be confused but I have been running 4.0 for about 4 months fine on the same hardware - The reason for all of the above is because that Cannot add storage on freshly deleted raid container. Feel free to join the discussion by leaving comments, and stay updated by subscribing to the RSS feed. Storage VMotion from NFS lun to ISCSI lun ?

  1. Try setting your SATA controller to IDE mode in the BIOS to do your install from the optical drive. (They "usually" default to SATA Mode (i.e. "AHCI mode"). 0 Message
  2. The Core i7 family is about the same as the E55xx or E56xx server processor family.
  3. Remove the 5gb LUN from the ESX Storage menu.
  4. You can try to install ESXi 4.0, then upgrade it to 4.1 as suggested earlier.

for Intel-VT to work correctly, the CPU, BIOS and Motherboard must all be enabled. Am I missing something?Thanks,-Stanley 1036Views Tags: none (add) This content has been marked as final. I rebooted and tried the above steps again but still same PSOD. Error During The Configuration Of The Host Nfs Error Unable To Mount Filesystem Reply With Quote 06-22-2012,02:24 PM #4 To-M View Profile View Forum Posts Private Message Visit Homepage Administrator Join Date Jun 2006 Posts 3,006 Try to disable the NFS service from the

This will list all of your options. Error During The Configuration Of The Host Cannot Open Volume Copyright Squidworks.net Send to Email Address Your Name Your Email Address Cancel Post was not sent - check your email addresses! It will ask you for the starting cylinder. browse this site You must once again log into the console or remote in through putty. 11.

If you get confused type "m" for menu. Error During The Configuration Of The Host Destroyvmfsdatastore Can Delete Partition Once you have su'd to root you must type in "vmkfstool -C vmfs3 /vmfs/device/disks/vmhba0:0:0:#" Were # is the number of the new partition. Also VT-D is not the same as VT, you would need to disable both. Notify me of new posts by email.

Error During The Configuration Of The Host Cannot Open Volume

Removed the NFS option and checked the status to make sure the screens were been refreshed and yes the status reported OFF and INACTIVE. http://vikashkumarroy.blogspot.com/2009/09/failed-to-update-disk-partition.html This should take 5 minutes or less to complete. 0 LVL 116 Overall: Level 116 VMware 109 Message Active today Expert Comment by:Andrew Hancock (VMware vExpert / EE MVE)2011-02-07 @TheChemic: Error During Configuration Of The Host Maybe external USB attached drive? 0 Message Active 2 days ago Author Comment by:j-teksolutions2011-02-17 I have picked up a USB cdrom testing in a couple of hrs will follow up Error During The Configuration Of The Host Failed To Update Disk Partition Information Guide to VMware standalone convertor VMotion keep failing at 78% with Error bad0007 How to present 6TB of LUN to Windows Server How to reset password for root on Ubantu ►

If you server is not on the Hardware Compatibility List, then there is a good reason why it's been dropped. news HCL link - http://goo.gl/YwWF9 Make sure that Intel VT or AMD-V is enabled on the BIOS before initiating the installation. 0 Message Active 2 days ago Author Comment by:j-teksolutions2011-02-07 I Solution: Boot into the raid controller. No other changes needed. Error During The Configuration Of The Host Nfs Error

Join & Ask a Question Need Help in Real-Time? I tried to post yesterday but had problems with my internet connection. Connect with top rated Experts 20 Experts available now in Live! http://invictanetworks.net/error-during/error-during-configuration-of-host.html Re: Error during the configuration of the host: Failed to get disk partition information DSTAVERT Feb 7, 2011 8:24 AM (in response to stan12345) Just how the size is calculated.

If your 1TB drives are actually a bit smaller (not uncommon) you may be able to create your datastore via the command line. Error During The Configuration Of The Host Config Spec Flags Cfg Version So I decided to check the host by using ILO and found PSOD. Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We

http://www.vm-help.com/esx40i/esx40_whitebox_HCL.php 0 LVL 28 Overall: Level 28 VMware 24 Message Expert Comment by:bgoering2011-02-07 Yes, the fatal error with 4.1 is usually VT related.

Because the drive is being used by the console OS you will probably get an error that says "WARNING: Re-reading the partition table failed with error 16: device or resource busy." Thanks everyone for your excellent help and expertise. 0 LVL 28 Overall: Level 28 VMware 24 Message Expert Comment by:bgoering2011-02-18 Great - glad you got it going 0 Write Comment The program is based upon the same curriculum as the Microsoft IT Certifications to build the skills students need to succeed at work and the preparation they need to validate those Error During The Configuration Of The Host Unable To Create Filesystem I am not attempting to discredit his solution as it is a valid one.

are you happy to stick at 4.0? 0 Message Active 2 days ago Author Comment by:j-teksolutions2011-02-16 I can stick at 4.0 - you had mentioned 4.1 is less buggy - I had run through the wizard and made sure that each of the ESX hosts had read/write access as well as “Root” access to the export/volume but I continued to get But when i wanted to complete the wizard, the following error came up: Now if you go on the Internet a search around you will find several references to this issue. check my blog Run fdisk /dev/sda.

We had been trying and trying to figure out this one. If this is your first visit, be sure to check out the FAQ by clicking the link above. If your vPower NFS server is added by IP, you need to specify VeeamBackup_XXX.XXX.XXX.XXX8.       Do not check the box for Mount NFS read only9.       Enter in to the Datastore name the Disabled VT-D no difference 2.

Type "n". If not please see below ** Hi, Im currently evaluating your product as a data store for VMware ESX4.0.0 Build 164009. I have then used the console ping command and can ping the ip address of the dss box and pinged successfully by entering its name "dss" ? UPDATE - 4.0 installed attaching storage again 0 LVL 116 Overall: Level 116 VMware 109 Message Active today Expert Comment by:Andrew Hancock (VMware vExpert / EE MVE)2011-02-16 Yes, vSphere Client

vihostupdate --server host name or IP address -i -b location of the ESXi upgrade ZIP bundle - B ESXi410-GA-esxupdate You have to do that before you do the GA by itself If you choose to use hardware that is not listed on the HCL, it's your risk. 0 LVL 28 Overall: Level 28 VMware 24 Message Expert Comment by:bgoering2011-02-17 Do you It is quite a bit less buggy than 4.0 0 Message Active 2 days ago Author Comment by:j-teksolutions2011-02-07 Bgoering...so strange I wanted to go 4.1 but I have the strangest The code you want is "fb".

February 12, 2010 at 2:53 AM Post a Comment Newer Post Older Post Home Subscribe to: Post Comments (Atom) IF YOU HAVE FEEDBACK ON MY BLOG PLEASE CLICK BELOW FeedBurner FeedCount The forum is managed by Open-E data storage software company. Here is the link again: http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1001489 If you didn't install ESX(i) to the same local datastore let us know... 0 LVL 2 Overall: Level 2 Message Expert Comment by:TheChemic2011-02-07 bgoering Did you enjoy this thread?

All the support instructors need to deliver great courses on Microsoft software is in the program. The change takes effect the next time you reboot the host.7.  Click OK. For issues related to the vPower NFS Service not starting please review: http://www.veeam.com/kb1094  How helpful is this article: 4 Most modern boards are supporting Intel-VT correctly. 0 Message Active 2 days ago Author Comment by:j-teksolutions2011-02-07 Yes this is a white box Specs INTEL DX58SO2 Extreme Series MB INTEL i7 After creating a new LUN on a Dell MD3000i, I wanted to add the new iSCSI LUN to my ESXi server.

When a LUN is larger than 2TB the 2TB is ignored and the excess beyond 2TB (or multiples) is presented. I'm just starting to search for a solution and found your post.