Home > Error For > Error For Command Write 10 Error Level Retryable Solaris 10

Error For Command Write 10 Error Level Retryable Solaris 10


If yes fix the problem with the port. 0 Kudos Reply The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard Enterprise. Talk With Other Members Be Notified Of ResponsesTo Your Posts Keyword Search One-Click Access To YourFavorite Forums Automated SignaturesOn Your Posts Best Of All, It's Free! Close Sign In Print Article Products Related Articles Article Languages Subscribe to this Article Manage your Subscriptions Problem In a Storage Foundation for Cluster File System (SFCFS)  environment, it is c1t1d0 is showing signs of impending failure or has failed already, as the case may be. get redirected here

Toolbox.com is not affiliated with or endorsed by any company listed at this site. Font with Dollars but no line through it When should I refuel my vehicle? If these are internal disks on a host: are there required slots to plug the disks in? Check san switch ports.

Error For Command Write 10 Error Level Retryable Solaris 10

from /var/adm/messages Solaris Page 1 of 2 1 2 > Thread Tools Search this Thread Display Modes

#1 06-13-2011 lramsb4u Registered User You can not post a blank message. c1t3d0 /[email protected],700000/[email protected]/[email protected],0 Specify disk (enter its number): A failing disk will show read or write errors in /var/adm/messages. AVAILABLE DISK SELECTIONS: 0.

  1. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed
  2. unix hard-drive solaris share|improve this question asked Nov 1 '13 at 17:34 help_me 105 add a comment| 1 Answer 1 active oldest votes up vote 0 down vote accepted As root,
  3. c1t5d0 /[email protected],600000/SUNW,[email protected]/[email protected],0/[email protected],06.
  4. In fact, SVM will not allow you to do metadetach and metaclear on a failed disk. # metadetach d0 d20 metadetach: solaris_1: d0: attempt an operation on a submirror that has
  5. Sorry, we couldn't post your feedback right now, please try again later.
  6. Re: Retryable warning msg Pascal Kreyer-Oracle Nov 4, 2013 9:10 AM (in response to 35369869-9b7f-49a1-a9d6-3f540ed90ea3) Check disks status in CAM (Common Array Manager).
  7. SCSI Transport -- the interface below the target drivers.   Encompasses generic "glue logic" and the HBA driver specific to the hardware and transport media in use.

Example 4: Sample SCSI messages related to some RAID level Admninistration operation scsi: [ID 107833 kern.warning] WARNING: /[email protected]/[email protected]/[email protected]/SUNW,[email protected]/[email protected],0/[email protected],3a (ssd9830): Error for Command: read(10) Error Level: Retryable scsi: [ID 107833 kern.notice] Requested All rights reserved. Ambrose Darwin replied Dec 14, 2011 This server has 2 JBODs with veritas volume manager. By joining you are opting in to receive e-mail.

CHECK CONDITION).   When SCSI standards define this specific Sense Data an interpretation will be printed in the message block by Solaris, otherwise it will be reported as vendor specific and Asc: 0x3f (reported Luns Data Has Changed), Ascq: 0xe, Fru: 0x0 Remove advertisements Sponsored Links solarishumble View Public Profile Find all posts by solarishumble Page 1 of 2 1 2 > « Previous Thread | Next Thread » Thread Tools Show Anandmeera replied Dec 18, 2011 Hi Darwin, Please provide the following output, #echo |format #vxdisk -e list One more thing to high light to you, when you about the replace the https://community.oracle.com/thread/2599650 Warnings are just that.

Security Violations =-=-=-=-=-=-=-=-=-= Jun 1 01:48:21 unix009 scsi: [ID 107833 kern.notice] ASC: 0x44 (internal target failure), ASCQ: 0x0, FRU: 0xbc The following are from /var/adm/messages Code: Jun 1 01:48:21 unix009 scsi: Join Us! *Tek-Tips's functionality depends on members receiving e-mail. c1t0d0 /[email protected],700000/[email protected]/[email protected],0 1. In veritas , vxdisk list , no errors...

Asc: 0x3f (reported Luns Data Has Changed), Ascq: 0xe, Fru: 0x0

Also it depends if RAID is setup or not. https://www.veritas.com/support/en_US/article.TECH146039 Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. Error For Command Write 10 Error Level Retryable Solaris 10 All product names are trademarks of their respective companies. Remove advertisements Sponsored Links lramsb4u View Public Profile Find all posts by lramsb4u #7 06-16-2011 solarishumble Registered User Join Date: Dec 2008 Last Activity: 14 October 2011, 8:05

Four line equality more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture http://invictanetworks.net/error-for/error-for-command-write10-error-level-retryable.html Because knowing if a disk has failed may save you a few steps when it's time to replace it. Attila Szabó replied Dec 14, 2011 +1 vote for replace the disk as soon as possible. from /var/adm/messages Hi all, I got the following error message from solaris 10 system.

SCSI status -- the highest level of information passed from logical unit and target to initiator which indicates the completion status of a CDB.  These include GOOD status, CHECK CONDITION, etc. What should be done to take care of this. AVAILABLE DISK SELECTIONS: 0. useful reference PCMag Digital Group AdChoices unused Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility

Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free. The disks are managed by SVM and "metadb" is showing the flags as "a" Are there any tests or indications as to check/see if the disk is actually failing or was Strategies for creating 3D text Place all sed commands into one shell script file Combination of liquid hydrogen and liquid oxygen Is masking before unsigned left shift in C/C++ too paranoid?

Red Flag This Post Please let us know here why this post is inappropriate.

Noor Arsath replied Dec 14, 2011 Hard errors for any disk should be 10 or more. Please enter a title. Terms of use for this information are found in Legal Notices.

Related Articles Article Languages x Translated Content Please note that this document is a translation from English, and may c1t0d0 /[email protected],600000/SUNW,[email protected]/[email protected],0/[email protected],01.

c1t2d0 /[email protected],600000/SUNW,[email protected]/[email protected],0/[email protected],03. Thanks in advance! Is there a place in academia for someone who compulsively solves every problem on their own? this page The time now is 08:30 AM. - Contact Us - Unix & Linux - unix commands, linux commands, linux server, linux ubuntu, shell script, linux distros. - Advertising - Top

Related 3 Essential Components for a Strong Enduser Security ... I_T_L nexus -- a path from a specific initiator via a specific target port to a specific logical unit.   In a multipath environment a single logical unit may have multiple Resources Join | Indeed Jobs | Advertise Copyright © 1998-2016 ENGINEERING.com, Inc. c2t2d0 /[email protected],600000/[email protected]/SUNW,[email protected]/[email protected],0/[email protected],09.

Is it ok to replace when replication occurs. You may also zero in on the disk area to test by selecting "setup" and setting the starting/ending block of the test around the Requested Block area. Join Date: Feb 2004 Last Activity: 11 October 2016, 6:35 AM EDT Location: NM Posts: 10,832 Thanks: 449 Thanked 969 Times in 900 Posts You have a bad disk block. Additional Sense Code Qualifier (ASCQ) -- part of the Sense Data.   The ASCQ further refines the SK/ASC.  There may be vendor specific values defined in addition to those defined in

c2t0d0 /[email protected],600000/[email protected]/SUNW,[email protected]/[email protected],0/[email protected],07. I got following error in /var/adm/messages Dec 12 20:03:36 devel01 scsi: [ID 107833 kern.warning] WARNING: /[email protected],600000/[email protected]/[email protected],0 (sd18): Dec 12 20:03:36 devel01 Error for Command: write(10) Error Level: Retryable Dec 12 20:03:36 c2t3d0 /[email protected],600000/[email protected]/SUNW,[email protected]/[email protected],0/[email protected],010. If you still have errors on the same disk, the disk could not 'heal' itself.

The Following User Says Thank You to jim mcnamara For This Useful Post: lramsb4u(06-14-2011) Remove advertisements Sponsored Links jim mcnamara View Public Profile Find all posts by jim mcnamara #3 I have not seen the messages re-occurring.