Home > Failed To > Error Failed To Sync Data On Replica Device

Error Failed To Sync Data On Replica Device

Contents

The SRM database was installed on the vCenter server instance as vCenter database.  And just like default vCenter installation I choose use of localhost\administrator  for owner of database.  The database does That specific filer also had SATA disks, while the other only had FC disks. Please type your message and try again. 3 Replies Latest reply: Nov 23, 2015 1:00 PM by gs_khalsa Failed to sync data on replica consistency group AndrewP27 Oct 26, 2015 7:14 Placeholder vms are there as well. my review here

Will it ever be fixed? 0 Kudos Reply All Forum Topics Previous Topic Next Topic The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard Enterprise. Required fields are marked *Comment Name * Email * Website Notify me of follow-up comments by email. So let's jump back into SRM and click Reprotect Select ‘I understand that this operation cannot be undone.' and click Next Let's click Start and watch the process in action. One concern is the footprint SRM leaves on the VM that has been replicated.

Error Failed To Sync Data On Replica Device

Any ideas for a workaround? 0 0 08/04/14--21:41: SRA for IBM Storewize - update proecedure question Contact us about this article Hi,   I've to update SRA for IBM Storewize V7000 To make sure the testing went smooth I created some scripts and a prompt in the recoveryplans to make sure everything works fine. I have setup the necessary and done the successful failover, however, I need to change the replication direction back to the original site to fail back. Device found is neither of SAN type nor of the NAS type.

Failed to create snapshot of replica device 0F78. SAN or NFS? One of the most common errors caused by such configuration is: Error: Failed to sync data on replica device ‘/vol/volume_name/lun#. Re: Test fails with SRM5 using MirrorView SRA cqde Jan 25, 2012 2:25 PM (in response to dbroome-ici) Info was burried in which Doc?I have searched all of ECN and cannot

Please remove the existing version and run setup again to continue."   The plug in wasn't installed previously so there's nothing to remove. Failed To Sync Data On Replica Consistency Group Recoverpoint The prompt configuration is like this: Name: Wait for the Create Writable Storage Snapshots to complete. Many admins still believe that using vSphere Replication with vCenter Site Recovery Manager for data center migration you will still lose up to 15 minutes of Data. Let's do the obligatory ping test via DNS, again success.

I am not sure for whatever reason during VMware SRM setup, the VMware Site Recovery Manager service got installed using local system rather than the service account entered during the installation. The test and failover works fine if you uncheck the synch option. The following information is the error message that we got from vCenter Site Recovery Manager.   Error - Failed to sync data on replica consistency group 'VM'. Re: Test fails with SRM5 using MirrorView SRA cqde Jan 26, 2012 11:18 AM (in response to cqde) I worked with the SRA developers to solve this.The logs showed a problem

Failed To Sync Data On Replica Consistency Group Recoverpoint

SRM 5.5 Contact us about this article Setting up SRM 5.5 using RecoverPoint new install and setup.   I have downloaded and installed the recommended SRA Adapter in my SRM server, see this Because this was just a test, when we were done we decommissioned the recovery site test environment and uninstalled SRM from the protected site.   Because the recovery site was removed Error Failed To Sync Data On Replica Device Error - Failed to demote source device '0A36'. These are the errors we got: Error - Failed to sync data on replica device '/vol//'.

You can leave it un-ticked so it assumes it will have admin rights to every consistency group. this page OK what happened? Schema is default. 3.) Username (which is a windows domain name) has dbo, bulk creator etc rights 4.) Username has Full Local Admin rights on the VCENTER Server where SRM has Send to Email Address Your Name Your Email Address Cancel Post was not sent - check your email addresses!

The last thing worth mentioning is that VMware Site Recovery Manager 4 will be compatible with vDistributed switches. Internal error: std::exception 'class Vmacore::InvalidArgumentException' "Invalid argument".   it's error at step 4 = Create Writeable Storage Snapshot   what I need to check ? After several attempts to root cause and tried different installation methods, the way to get the installation to complete and setup correctly was to login to the system AS the domain http://invictanetworks.net/failed-to/error-failed-to-create-display-device.html However I'm keen to hear real world thoughts on the two blended.

From what I see SRAs are very often where SRM runs into problems. I know I can do a test failure to confirm but I'm not in that position at the moment as company policy says I can only do the test during a Let us know : My Account Welcome, Log out View or Edit Profile Find a CommunityExploreContentPeoplePlacesEventsEvents HomeEMC ForumEMC WorldLive EventsCreateLogin / RegisterHelpSearch  Find Communities by: Category | Product Big Data

SRA command 'testFailoverStart' failed for device '0F78'.

  1. Share This Page Legend Correct Answers - 10 points Menu Close HomeAboutBlog RSS FeedsBucket List 0 VMware SRM - Failed to Sync data on Replica Devices Posted on 11 May 2013
  2. As a matter of fact the testing workflow requires a FlexClone license but the other workflows (Recovery\Reprotect) do not I am thinking there may have been an issue with the igroup
  3. This fixed first issue.

VMF-TEST01 is in a good place, as it's being replicated to our DR site Let's get it on, into SRM, then click on Recovery Plans, then onto Recovery Steps (so that They have released the new version of VMware Site Recovery Manager SRM which will support VMware vSphere. View the server log for more information. There isn't an upgrade to the one I'm using. 0 0 07/24/14--08:35: SRM DataCenter migration Question Contact us about this article Hello,   We are looking to use SRM to migrate

It was contributed by me and is published “as is”. I thought I will share the good news with every one. Community HPE StoreVirtual Storage / LeftHand CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible useful reference Share this:Click to email (Opens in new window)Click to share on LinkedIn (Opens in new window)Click to share on Twitter (Opens in new window)Like this:Like Loading...

At DR, VMF-TEST01 is up and running and it's IP Address has been successfully changed. None" Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page mattkoz Occasional Visitor Options Mark An error occurred while preparing for failover on stand alone devices. Blog at WordPress.com.

Re: Test fails with SRM5 using MirrorView SRA kendcollins Jan 26, 2012 6:56 AM (in response to cqde) Hi,MirrorView Insight is for SRM 4 or earlier and is not compatible with Should I have uninstalled them before hand? Recovery Plan Change Add Commands Now the recovery plan needs to be changed for this to be executed. We have spoken to EMC about the failback side of it, does it do deltas or full re sync and have had 2 conflicting answers back from them, this is an

That is a common error listed on the SRA IAG and the corrective action is to "Ensure that the device exists on the storage array and is of type NAS or Or buy me a beer?: Recently Changed Pages: View All Pages View All Q Pages ad admt aix apache backup blog bordermanager cisco cloud config dutch edirectory email fiber fix gpo where the problem is ? None" Have a P4000 with SANiQ 9.5.00.1215.0 - when I run a planned migration or test and have it synch the changes, SRM fails with: "Failed to sync data on replica